I.V. Cannula

NEEDLE

Siliconised, beveled, back cut ground stainless steel needle for smooth and painless venipuncture.

NEEDLE HUB

NEOTEC I.V.Cannula have full collar needle hub to prevent any destabilisation and bending of the needle during insertion.

NEEDLE COVER

Protects the needle from contamination. Prevents accidental damage to the catheter and needles.

CATHETER

All NEOTEC cannula are made of virgin PTFE (Poly Tetra Fluoro Ethylene) double tapered beveled tip siliconised catheter which offers:
High resistance to kinking without compromising biocompatibility. Minimum resistance during insertion due to low coefficient of friction and improved tip design. High chemical resistance reduces the chances of thrombogenecity.
Thin wall thickness of the catheter allows maximum flow rate for a specific gauge of cannulae.
Optimum trim distance. Catheter with radiopaque lines and non-radiopaque (transparent) are also available.

OPTIONAL CATHETER MATERIAL

Polyurethane (PU)
Fluorinated Ethylene Propylene (FEP)

FLASH BACK CHAMBER

Two piece flash back chamber allows monitoring of instantaneous flash of blood after venipuncture and identification of correct catheter placement. Specially designed to prevent any spillage of blood. Divided in two parts by a solid plastic wall. The Back half is used as rest for luer lock plug and can be transferred to the end of catheter hub to seal against blood leakage.

BLISTER PACKING

All the I.V.Cannula are sterile and individually packed in rigid blister and are sealed in peel open type medical tyvek/paper.

Safety I.V. catheter with injection valve

FEATURES

  • Protection against needlestick injuries.
  • No special cannulation technique required.
  • Self-activating Tip cover technology, no user activation required.
  • Safety mechanism cannot be bypassed.
  • Backcut bevel reduces pain of insertion.
  • Advanced Tip design for smoother transition.
  • Transparent Flashback Chamber with Hydrophobic Filter for consistent flashback.
  • Available in PTFE, FEP and PUR.

CAUTION

Do not try to reinsert a partially or completely withdrawn needle.

In case venipuncture is not successful, remove the needle first to activate safety mechanism, then withdraw catheter from patient.

Safety I.V. catheter without injection valve without wings

FEATURES

  • Protection against needlestick injuries.
  • No special cannulation technique required.
  • Self-activating Tip cover technology, no user activation required.
  • Safety mechanism cannot be bypassed.
  • Backcut bevel reduces pain of insertion.
  • Advanced Tip design for smoother transition.
  • Transparent Flashback Chamber with Hydrophobic Filter for consistent flashback.
  • Available in PTFE, FEP and PUR.

CAUTION

Do not try to reinsert a partially or completely withdrawn needle.

In case venipuncture is not successful, remove the needle first to activate safety mechanism, then withdraw catheter from patient.

I.V. Cannula with Injection Valve

FEATURES

  • Provided with injection site.
  • It has one way retreating valve to facilitate extra medication without allowing any back flow.
  • To inject medicine by a Syringe without needle thereby reducing the chances of infection and preventing needle stick injuries.
  • The valve is provided with specially designed cap incorporating a recessed plug with a protective skirt to effectively prevent contamination when the valve is not in use.
  • Colour coded valve cap for the size identification.
  • It offers safe and convenient method of atraumatic administration of medicine.
  • Angled and grooved wings offer easy fixation and prevent pistoning and rolling of cannula over the patient's body .
  • Disposable, sterile and non-pyrogenic.
  • Siliconised, ultra-sharp back-cut needle for painless venipuncture.
  • Kink resistant and biocompatible catheter with smooth surface for easy penetration.
  • Advance tip design provides smooth transition from needle to catheter.

Options Available

Radiopaque or Transparent catheter

Paper or Tyvek Packing

PTFE, FEP or PUR Catheter

I.V. Cannula - 1 Way (Without Valve, With Small Wings)

FEATURES

  • Larger flash back chamber and grip for ease of handling.
  • Small projection for identification of needle bevel.
  • Small wings help in keeping it in place and do not interfere even on a contoured surface.
  • Low profile.
  • Sterile, disposable, non-pyrogenic.
  • Colour coded body & wings for size identification.
  • Siliconised, ultra-sharp back-cut needle for painless venipuncture.
  • Kink resistant and biocompatible catheter with smooth surface for easy penetration.
  • Advance tip design provides smooth transition from needle to catheter.

Options Available

Radiopaque or Transparent catheter

Paper or Tyvek Packing

PTFE, FEP or PUR Catheter

I.V. Cannula - 1 Way (Without Valve, Without Wings)

FEATURES

  • Useful in high risk cases where no extra opening is permitted for risk of infection.
  • Symmetrical design facilitates cannulation at contoured surfaces.
  • Colour coded body for size identification.
  • Disposable, sterile and non-pyrogenic.
  • Transparent hub for easy flashback visualisation.
  • HYDROPHOBIC FILTER allows consistent flashback.
  • Siliconised, ultra-sharp back-cut needle for painless venipuncture.
  • Kink resistant and biocompatible catheter with smooth surface for easy penetration.
  • Advance tip design provides smooth transition from needle to catheter.

Options Available

HYDROPHOBIC FILTER allows consistent flashback.

With Hydrophobic Filter or Threaded Stopper.

Paper or Tyvek Packing or PEN type.

PTFE, FEP or PUR Catheter

Safety I.V. Cannula with Injection Valve

Step Wise Cannulation Guide

Step 1

  • Select suitable size of Safety I.V. Cannula & inspect visually to ascertain that package is intact.
  • Wash hand with antiseptic solution and wear gloves.
  • Apply tourniquet.
  • Disposable, sterile and non-pyrogenic.
  • Locate an accessible and suitable peripheral vein visually and confirm by palpation.
  • HYDROPHOBIC FILTER allows consistent flashback.
  • Disinfect the venipuncture site properly.

Step 2

  • Remove Safety I.V. Cannula from individual packaging.
  • Remove wing body clip upward.

Step 3

  • Remove needle cover by holding the wing body catheter hub of Safety I.V. Cannula and discard the needle cover.
  • Do not touch the catheter.

Step 4

  • Hold the Safety I.V. Cannula by Grip Pad keeping bevel face upward.
  • Puncture the vein with needle and confirm successful venipuncture by visualizing blood in flashback chamber.

Step 5

  • Push the projection till catheter is adequately into the vein.
  • Stabilize the device at Projection with Index Finger.
  • Holding the Grip Pad, pull the needle gently until you hear a click sound, which confirms locking of the needle into the safety chamber.

Step 6

  • Remove tourniquet.
  • Hold the I.V. Cannula at wing body catheter hub.
  • Put digital pressure away from catheter tip.
  • Turn the Safety Chamber either left or right and remove from the wing body catheter hub.
  • Discard the safety chamber according to general hospital practice.
  • Connect the I.V. Infusion line.

Safety I.V. Cannula 1 Way - Without Valve, Without Wings

Step Wise Cannulation Guide

Step 1

  • Select suitable size of Safety I.V. Cannula & inspect visually to ascertain that package is intact.
  • Wash hand with antiseptic solution and wear gloves.
  • Wash hand with antiseptic solution and wear gloves.
  • Apply tourniquet.

Step 2

  • Remove Safety I.V. Cannula from individual packaging.
  • Remove Needle Cover by holding the Grip Pad and discard the needle cover.
  • Do not touch the catheter.

Step 3

  • Hold the Safety I.V. Cannula by Grip Pad keeping needle bevel upward.
  • Puncture the vein with needle and confirm successful venipuncture by visualizing blood inthe flashback chamber.

Step 4

  • Push the projection till catheter is adequately into the vein.
  • Stabilize the device at Projection with Index Finger.
  • Holding Grip Pad, pull the needle gently until you hear a click sound, which confirms locking 
of the needle into the safety chamber.

Step 5

  • Remove tourniquet.
  • Put digital pressure away from catheter tip.
  • Hold the I.V. Cannula at coloured catheter hub.
  • Turn the Safety Chamber either left or right and remove from the coloured catheter hub.
  • Discard the safety chamber according to general hospital practice.
  • Connect the I.V. Infusion line.

3 Way Stop Cock

Features

  • Minimal dead-spaces in ports for accurate drug administration.
  • Uniform smooth bore throughout permits maximum infusion flow and prevents turbulence as well as formation of air bubbles.
  • Designed to withstand the pressure upto 6 bars (87 psi)
  • Rotating luer lock and threaded female ports facilitate safe and secure connection to luers of other systems.
  • Arrow indication marks on the tap to indicate the direction of flow.
  • Low profile for stable and safe positioning on the patient's body.
  • Transparent base facilititates observation of flow.
  • Internationally accepted 6% luer taper for compatibility with any standard product. Disposable, sterile and non-pyrogenic.

Size & Technical Specifications

Extension Tubing with Integrated 3 Way Stop Cock

Features

  • Three way stopcock with integrated extension tubing for less manipulation during intravenous administration of fluids/ drugs through an IV Cannula.
  • Available in lengths 5,7,10,25,50,75,100,125,150, 200, 250 cms.
  • Sterile disposable and pyrogen free

INJECTION STOPPER

img

Features

  • Latex/latex free plug with leakage free fitting for effective flushing of catheter or drawing of blood samples.
  • Minimum Dead space.
  • Universal 6% taper as per ISO 594, compatible with any standard product.
  • Sterile, disposable and pyrogen free.

LUER LOCK CAP

luer-lock

Features

  • To block IV Cannulas when not in use.
  • Sterile, disposable and pyrogen free.

COMBI LUER LOCK

luer-lock

Features

  • To block IV Cannulas when not in use.
  • Sterile, disposable and pyrogen free.

MANUAL RETRACTABLE SAFETY SYRINGE

Features

Same Injection Technique

  • No change in injection technique required for manual retractable syringe.

Safety First

  • After use, the locking device manually captures the needle within the barrel.

No Reuse by Design

  • The needle cannot be re-used once the needle is contained within the barrel.

Locking Confirmation

  • The user can feel when the locking system mechanism is activated.

Breakable Plunger

  • Once the needle has been used the device plunger can be broken away to prevent further use.

Highest Standards

  • Meets International Standards for Medical Devices. No Leakage. Low Dead Space.

Availability :

  • U100 0.3ml, 0.5ml, 1ml, Fixed needle, 28G-30G x 5/16’‿ ½‿/li>
  • 3ml, 5ml, 10ml, 20ml
    Syringe without needle,
    Syringe with needle 18-27G x 1’‿ 1 ½’‿/li>

SAFETY HYPODERMIC NEEDLE

img

Features

High Quality, Detachable Universal Needle

  • Provides optimum patient comfort
  • Bevel-Up orientation for low angle injection.
  • Fits any conventional Luer Lock or Luer Slip syringe.
  • Allows for interchange of needles for aspiration and administration.

ISO Colour Coded Safety Cover

  • Provides easy identification of Needle Gauge.
  • Two cover sizes to accommodate short and long needle lengths
  • Can be adjusted for left or right handed users.

Enhanced Safety Locking Mechanism

  • Locking clips secure the needle inside the safety cover.

Single-Handed Activation

  • Requires minimal training.
  • Almost no change in hand position required to activate.

Audible Click Upon Activation

  • Signals that cover is securely locked in place over the needle.

SAFETY SCALP VEIN SET AND BLOOD COLLECTION NEEDLE

img

Features

  • Soft wings are easy to grip and fix to patient
  • Flexible tubing reaches more body surface and tolerates more patient movement
  • Unique protective sheath to prevent needle-stick injury
  • ISO color coding for easy recognition
  • Luer Lock and Luer slip fittings
  • Quality needles for patient comfort
tab

RETRACTABLE SAFETY SCALPEL

img

Features

  • New Generation Scalpel to reduce the risk of injuries associated with sharp edges could lead to high contracting diseases like HIV/AIDS, Hepatitis A, B, C etc.
  • The Safety Scalpel is designed to prevent from accidental needle sticks.
  • Glides easily and comfortably into locked position.
  • Metric ruler assists in determining length of incision.
  • Ribbed handle for perfect hold in gloved hands.

Instructions for use

  • Remove scalpel from sterile pack.
  • Slide the latch forward until it is locked and blade is exposed and ready for use.
  • Push back after use with force until a click is heard and felt.
  • The Scalpel is now ready for disposal.